S001

Beam to column with endplate.

Allowed Profiles

Profile

H

L

U

Pipes

Tubes

Beam (2)

✔️

✔️

✔️

✔️

✔️

Column (1)

✔️

Parameters

S001 has several singular parameters related to column position stiffeners and beam position. There is a checkbox. If marked, four stiffeners will be taken into account and eventually created in Tekla.

Column position dropdown allows you to restrain the joint to be applied only to a beam-to-web or beam-to-flange connection. Calculations and Tekla results will be afected.

Identifier

Description

Appearing in

Units

Stiffeners

If checked, four stiffeners will be created

None

None

Column Position

Part of the column connected to the beam

Any position Bolts at flange Bolts at web or cut

None